目前位置 : now_page 首頁homepage >  增壓系列 Boost series > 增壓系列-增壓缸 Power-Unit Cylinder > 理論出力及空氣消耗量 Theoretical force & Consumption > 直壓式出力7.5噸增壓缸 Direct Operated/ 7.5Ton   回上一頁 back
   

理論出力及空氣消耗量(往返一次之耗氣量):
Theoretical force & Consumption(The values for a complete "down stroke/return" cycle):

編碼

總出力/kg

回程拉力/kg

耗氣量(往返一次)/L

DPD-075-000-075

( 1442.6 x Pd )

( 157 x Pd )

( 2.430 x Pd + 2.509 ) / 1.033

DPD-075-000-150

( 4.653 x Pd + 4.804 ) / 1.033


註1).Pd:氣壓源(Driven pressure)-- kg/cm2
舉例:設增壓缸規格為DPD-075-000-075,當操作壓力為5 kg/cm2,則增壓缸總出力及往返一次之耗氣量為:1442.6 × 5 = 7213 kg   ( 2.430 × 5 + 2.509 ) = 14.19ℓ
Example 1:If the power unit code No. DPD-075-000-075 , operating pressure is 5 kg/cm2, so force of the Power unit Cylinder and the consumption for a complete "down stroke/return" cycle is: 1442.6 × 5 = 7213 kg   ( 2.430 × 5 + 2.509 ) = 14.19ℓ