目前位置 : now_page 首頁homepage >  增壓系列 Boost series > 增壓系列-增壓缸 Power-Unit Cylinder > 理論出力及空氣消耗量 Theoretical force & Consumption > 直壓式出力10噸增壓缸 Direct Operated/ 10Ton   回上一頁 back
   

理論出力及空氣消耗量(往返一次之耗氣量):
Theoretical force & Consumption(The values for a complete "down stroke/return" cycle):

編碼

總出力/kg

回程拉力/kg

耗氣量(往返一次)/L

DPD-100-000-075

( 1986 x Pd )

( 181.4 x Pd )

( 3.279 x Pd + 3.386 ) / 1.033

DPD-100-000-150

( 6.324 x Pd + 6.529 ) / 1.033


註1).Pd:氣壓源(Driven pressure)-- kg/cm2
舉例:設增壓缸規格為DPD-100-000-150,當操作壓力為7 kg/cm2,則增壓缸總出力及往返一次之耗氣量為:1986 × 7 = 13902 kg   ( 6.324 × 7 + 6.529 ) = 49.17ℓ