理論出力及空氣消耗量(往返一次之耗氣量):
Theoretical force & Consumption(The values for a complete "down stroke/return" cycle):
編碼
|
總出力/kg
|
回程拉力/kg
|
耗氣量(往返一次)/L
|
DPD-030-000-075
|
( 615.8 x Pd )
|
( 66 x Pd )
|
( 1.036 x Pd + 1.070 ) / 1.033
|
DPD-030-000-150
|
( 1.980 x Pd + 2.044 ) / 1.033
|
註1).Pd:氣壓源(Driven pressure)-- kg/cm2
舉例:設增壓缸規格為DPD-030-000-150,當操作壓力為6 kg/cm2,則增壓缸總出力及往返一次之耗氣量為:615.8 × 6 = 3695 kg ( 1.980 × 6 + 2.044 ) = 13.48ℓ
Example 1:If the power unit code No. DPD-030-000-150 , operating pressure is 6 kg/cm2, so force of the Power unit Cylinder and the consumption for a complete "down stroke/return" cycle is: 615.8 × 6 = 3695 kg ( 1.980 × 6 + 2.044 ) = 13.48ℓ